U-VALUE - FLOORS
FLOORS SOLUTIONS - Solid Ground
The tables below provide a quick and easy reference guide to the thickness of insulation
required to meet the stated U-values for floors. | |
THICKNESS IN MMU-Value 0.25 |
| |
Construction |
| (100mm Concrete slab, Insulation, Membrane (any), 65mm Screed) |
Using the charts: The U-value for floors can be calculated using a perimeter to area ratio (P:A).
To determine the thickness of insulation required, read up for length and across for width of the floor
(ie using the chart below 5 x 4 floor = 65mm). |
CELOTEX TUFF-R ™ GA3000Z
KINGSPAN THERMAFLOOR TF70/TP10 ZERO ODP
|
0.023 LAMBDA λ
|
| |
|
THICKNESS IN MM |
 |
15 |
75 |
70 |
65 |
60 |
55 |
50 |
50 |
45 |
45 |
40 |
40 |
40 |
35 |
35 |
35 |
14 |
75 |
70 |
65 |
60 |
55 |
50 |
50 |
45 |
45 |
40 |
40 |
40 |
35 |
35 |
35 |
13 |
75 |
70 |
65 |
60 |
55 |
50 |
50 |
45 |
45 |
45 |
40 |
40 |
40 |
40 |
35 |
12 |
75 |
70 |
65 |
60 |
55 |
55 |
50 |
50 |
45 |
45 |
45 |
40 |
40 |
40 |
40 |
11 |
75 |
70 |
65 |
60 |
55 |
55 |
50 |
50 |
50 |
45 |
45 |
45 |
40 |
40 |
40 |
10 |
75 |
70 |
65 |
60 |
55 |
55 |
50 |
50 |
50 |
45 |
45 |
45 |
45 |
40 |
40 |
9 |
75 |
70 |
65 |
60 |
60 |
55 |
55 |
50 |
50 |
50 |
50 |
45 |
45 |
45 |
45 |
8 |
75 |
70 |
65 |
60 |
60 |
55 |
55 |
50 |
50 |
50 |
50 |
50 |
45 |
45 |
45 |
7 |
75 |
70 |
65 |
65 |
60 |
60 |
55 |
55 |
55 |
50 |
50 |
50 |
50 |
50 |
50 |
6 |
75 |
70 |
65 |
65 |
60 |
60 |
60 |
55 |
55 |
55 |
55 |
55 |
50 |
50 |
50 |
5 |
75 |
70 |
65 |
65 |
65 |
60 |
60 |
60 |
60 |
55 |
55 |
55 |
55 |
55 |
55 |
4 |
75 |
70 |
70 |
65 |
65 |
65 |
65 |
60 |
60 |
60 |
60 |
60 |
60 |
60 |
60 |
3 |
75 |
70 |
70 |
70 |
65 |
65 |
65 |
65 |
65 |
65 |
65 |
65 |
65 |
65 |
65 |
2 |
75 |
75 |
70 |
70 |
70 |
70 |
70 |
70 |
70 |
70 |
70 |
70 |
70 |
70 |
70 |
1 |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
70 |
| |
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
| |
|
LENGTH (metres) |
DOW FLOORMATE 200-X/500-X/STYROFOAM SP-X
KNAUF INSULATION - POLYFOAM FLOORBOARD STANDARD |
0.029 LAMBDA λ |
THICKNESS IN MM |
 |
15 |
95 |
85 |
80 |
75 |
70 |
65 |
60 |
60 |
55 |
50 |
50 |
50 |
45 |
45 |
40 |
14 |
95 |
85 |
80 |
75 |
70 |
65 |
60 |
60 |
55 |
55 |
50 |
50 |
45 |
45 |
45 |
13 |
95 |
85 |
80 |
75 |
70 |
65 |
65 |
60 |
55 |
55 |
55 |
50 |
50 |
45 |
45 |
12 |
95 |
85 |
80 |
75 |
70 |
65 |
65 |
60 |
60 |
55 |
55 |
50 |
50 |
50 |
50 |
11 |
95 |
85 |
80 |
75 |
70 |
65 |
65 |
60 |
60 |
60 |
55 |
55 |
55 |
50 |
50 |
10 |
95 |
85 |
80 |
75 |
70 |
70 |
65 |
65 |
60 |
60 |
60 |
55 |
55 |
55 |
50 |
9 |
95 |
85 |
80 |
95 |
75 |
70 |
65 |
650 |
60 |
60 |
60 |
60 |
55 |
55 |
55 |
8 |
95 |
85 |
80 |
95 |
75 |
70 |
65 |
65 |
60 |
60 |
60 |
60 |
55 |
55 |
55 |
7 |
95 |
85 |
85 |
80 |
75 |
75 |
70 |
70 |
65 |
65 |
65 |
65 |
65 |
60 |
60 |
6 |
95 |
85 |
85 |
80 |
75 |
75 |
75 |
70 |
70 |
70 |
65 |
65 |
65 |
65 |
65 |
5 |
95 |
90 |
85 |
80 |
80 |
75 |
75 |
75 |
75 |
70 |
70 |
70 |
70 |
70 |
70 |
4 |
95 |
90 |
85 |
85 |
80 |
80 |
80 |
80 |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
3 |
95 |
90 |
90 |
85 |
85 |
85 |
85 |
80 |
80 |
80 |
80 |
80 |
80 |
80 |
80 |
2 |
95 |
90 |
90 |
90 |
90 |
85 |
85 |
85 |
85 |
85 |
85 |
85 |
85 |
85 |
85 |
1 |
95 |
95 |
95 |
95 |
95 |
95 |
95 |
85 |
95 |
95 |
95 |
95 |
95 |
95 |
95 |
| |
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
| |
|
LENGTH (metres) |
| |
U-Value 0.25 |
| |
Construction |
| (100mm Concrete slab, Insulation, Membrane (any), 65mm Screed) |
Using the charts: The U-value for floors can be calculated using a perimeter to area ratio (P:A).
To determine the thickness of insulation required, read up for length and across for width of the floor. |
KNAUF INSULATION POLYFOAM
FLOORBOARD EXTRA
|
Thickness
(MM) |
LAMBDA
λ |
| (Formerly Polyfoam Plus Floorboard (350) |
25-35-50 |
0.029 |
65-75 |
0.031 |
100 |
0.034 |
|
KNAUF INSULATION POLYFOAM
FLOORBOARD EXTRA |
Thickness
(MM) |
LAMBDA
λ |
| (Formerly Polyfoam Plus Floorboard (350) |
50 |
0.029 |
75 |
0.031 |
100 |
0.034 |
|
| |
|
| |
|
| All highlighted figures = a double layer of insulation |
75 |
= 50 mm + 25mm or 100mm (single layer) |
85 |
= 50 mm + 35mm or 100mm (single layer) |
100 |
= 75 mm + 25mm or 2 layers of 50mm |
| |
Due to varying Lambda values between the differing thickness of insulation boards,
a double layer of insulation may be used to achieve specific U-values |
|
THICKNESS IN MM |
 |
15 |
100 |
100 |
85 |
75 |
65 |
65 |
65 |
65 |
65 |
50 |
50 |
50 |
50 |
50 |
50 |
14 |
100 |
100 |
85 |
75 |
75 |
75 |
65 |
65 |
65 |
65 |
50 |
50 |
50 |
50 |
50 |
13 |
100 |
100 |
85 |
75 |
75 |
75 |
65 |
65 |
65 |
65 |
50 |
50 |
50 |
50 |
50 |
12 |
100 |
100 |
85 |
75 |
75 |
75 |
65 |
65 |
65 |
65 |
65 |
50 |
50 |
50 |
50 |
11 |
100 |
100 |
85 |
75 |
75 |
75 |
65 |
65 |
65 |
65 |
65 |
65 |
50 |
50 |
50 |
10 |
100 |
100 |
85 |
75 |
75 |
75 |
75 |
65 |
65 |
65 |
65 |
65 |
65 |
65 |
50 |
9 |
100 |
100 |
85 |
75 |
75 |
75 |
75 |
75 |
65 |
65 |
65 |
65 |
65 |
65 |
65 |
8 |
100 |
100 |
85 |
75 |
75 |
75 |
75 |
75 |
75 |
65 |
65 |
65 |
65 |
65 |
65 |
7 |
100 |
100 |
85 |
85 |
75 |
75 |
75 |
75 |
75 |
75 |
65 |
65 |
65 |
65 |
65 |
6 |
100 |
100 |
85 |
85 |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
65 |
5 |
100 |
100 |
100 |
85 |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
4 |
100 |
100 |
100 |
85 |
85 |
85 |
85 |
85 |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
3 |
100 |
100 |
10 |
100 |
100 |
85 |
85 |
85 |
85 |
85 |
85 |
85 |
85 |
85 |
85 |
2 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
1 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
| |
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
| |
|
LENGTH (metres) |
U-Value 0.25 |
| |
Construction |
| (100mm Concrete Slab, Insulation, Membrane (any), 65mm Screed) |
Using the charts: The U-value for floors can be calculated using a perimeter to area ratio (P:A).
To determine the thickness of insulation required, read up for length and across for width of the floor. |
DOW FLOORMATE 700-A
VENCEL RESIL JABFLOOR 100
|
0.036 LAMBDA λ |
THICKNESS IN MM |
 |
15 |
115 |
105 |
100 |
90 |
85 |
80 |
70 |
65 |
65 |
60 |
60 |
55 |
55 |
50 |
50 |
14 |
115 |
105 |
100 |
90 |
85 |
80 |
70 |
70 |
65 |
60 |
60 |
55 |
55 |
50 |
50 |
13 |
115 |
105 |
100 |
90 |
85 |
80 |
75 |
70 |
65 |
65 |
60 |
60 |
60 |
55 |
55 |
12 |
115 |
105 |
100 |
90 |
85 |
80 |
75 |
70 |
70 |
65 |
650 |
60 |
60 |
55 |
55 |
11 |
115 |
105 |
100 |
95 |
85 |
80 |
75 |
70 |
70 |
65 |
65 |
65 |
60 |
60 |
60 |
10 |
115 |
105 |
100 |
95 |
90 |
80 |
75 |
75 |
70 |
70 |
65 |
65 |
65 |
60 |
60 |
9 |
115 |
105 |
100 |
95 |
90 |
80 |
80 |
75 |
75 |
70 |
70 |
70 |
65 |
65 |
65 |
8 |
115 |
105 |
100 |
95 |
90 |
80 |
80 |
75 |
75 |
75 |
70 |
70 |
70 |
70 |
65 |
7 |
115 |
110 |
100 |
95 |
95 |
85 |
80 |
80 |
80 |
75 |
75 |
75 |
75 |
70 |
70 |
6 |
115 |
110 |
100 |
100 |
95 |
90 |
85 |
80 |
80 |
80 |
80 |
80 |
80 |
80 |
80 |
5 |
115 |
110 |
100 |
100 |
100 |
95 |
95 |
90 |
90 |
90 |
85 |
85 |
85 |
85 |
85 |
4 |
115 |
110 |
105 |
100 |
100 |
100 |
95 |
95 |
95 |
95 |
95 |
90 |
90 |
90 |
90 |
3 |
115 |
110 |
110 |
105 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
2 |
115 |
115 |
110 |
110 |
110 |
110 |
110 |
105 |
105 |
105 |
105 |
105 |
105 |
105 |
105 |
1 |
120 |
115 |
115 |
115 |
115 |
115 |
115 |
115 |
115 |
115 |
115 |
115 |
115 |
115 |
115 |
| |
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
| |
|
LENGTH (metres) |
VENCEL RESIL JABFLOOR 70
ROCKWOOL ROCKFLOOR
|
0.038 LAMBDA λ |
THICKNESS IN MM |
 |
15 |
120 |
110 |
105 |
95 |
90 |
85 |
80 |
75 |
70 |
70 |
65 |
60 |
60 |
55 |
55 |
14 |
120 |
110 |
105 |
95 |
90 |
85 |
80 |
75 |
75 |
70 |
65 |
65 |
60 |
60 |
55 |
13 |
120 |
110 |
105 |
95 |
90 |
85 |
80 |
75 |
75 |
70 |
70 |
65 |
65 |
60 |
60 |
12 |
120 |
110 |
105 |
95 |
90 |
85 |
80 |
80 |
75 |
75 |
70 |
70 |
65 |
65 |
60 |
11 |
120 |
110 |
105 |
95 |
90 |
85 |
85 |
80 |
80 |
75 |
75 |
70 |
70 |
65 |
65 |
10 |
120 |
110 |
105 |
100 |
95 |
90 |
85 |
80 |
80 |
75 |
75 |
75 |
70 |
70 |
70 |
9 |
120 |
110 |
105 |
100 |
95 |
90 |
85 |
85 |
80 |
80 |
80 |
75 |
75 |
75 |
70 |
8 |
120 |
115 |
105 |
100 |
95 |
90 |
90 |
85 |
85 |
80 |
80 |
80 |
75 |
75 |
75 |
7 |
120 |
115 |
110 |
105 |
100 |
95 |
90 |
90 |
85 |
85 |
85 |
80 |
80 |
80 |
80 |
6 |
120 |
115 |
110 |
105 |
95 |
95 |
90 |
90 |
90 |
85 |
85 |
85 |
85 |
85 |
85 |
5 |
120 |
115 |
110 |
105 |
105 |
100 |
100 |
95 |
95 |
95 |
90 |
90 |
90 |
90 |
90 |
4 |
125 |
115 |
110 |
110 |
105 |
105 |
105 |
100 |
100 |
100 |
95 |
95 |
95 |
95 |
95 |
3 |
125 |
120 |
115 |
110 |
110 |
110 |
110 |
105 |
105 |
105 |
105 |
105 |
105 |
105 |
105 |
2 |
125 |
120 |
120 |
115 |
115 |
115 |
115 |
115 |
110 |
110 |
110 |
110 |
110 |
110 |
110 |
1 |
125 |
125 |
125 |
125 |
120 |
120 |
120 |
120 |
120 |
120 |
120 |
120 |
120 |
120 |
120 |
| |
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
| |
|
LENGTH (metres) |
U-Value 0.22 |
| |
Construction |
| (100mm Concrete slab, Insulation, Membrane, 65mm Screed) |
Using the chart: The elemental U-value for floors can be calculated using a perimeter to area ration (P:A).
P = The exposed floor perimeter length in metres. A = the floor area in square metres.
In order to determine the P:A, the length of perimeter is divided by the the floor area.
Eg. a 5 x 4 floor (Perimeter = 18mm & Area = 20m2). The P/A = 0.9
The table below lists the thickness of different insulation materials required to provide a U-value of 0.22 W/m2K. |
LAMBDA
λ |
0.023 |
0.025 - 0.021 |
0.038 |
0.036 |
0.030 |
0.029 |
0.038 |
P/A
RATIO |
KINGSPAN
THERMAFLOOR
TF70 ZERO ODP &
TP10 ZERO ODP
CELOTEX TUFF-RTM
ZERO GA3000Z
35MM - 90MM
CELOTEX T-BREAKTM
TB 3000
12MM - 30MM |
KINGSPAN
KOOLTHERM K3
FLOORBOARD |
JABFLOOR 70 |
JABFLOOR 100 |
JABLO |
FLOORMATE
200-X/500X
STYROFOAM
SP-X |
ROCKFLOOR |
| |
THICKNESS
IN MM |
THICKNESS
IN MM |
THICKNESS
IN MM |
THICKNESS
IN MM |
THICKNESS
IN MM |
THICKNESS
IN MM |
THICKNESS
IN MM |
| |
|
|
|
|
|
|
|
0.1 |
20 |
20 |
- |
- |
- |
- |
- |
0.15 |
Celotex 20 |
- |
25 |
20 |
25 |
25 |
- |
0.2 |
30 |
35 |
50 |
45 |
40 |
40 |
50 |
0.25 |
- |
- |
- |
- |
60 |
60 |
- |
0.3 |
50 |
50 |
80 |
75 |
65 |
70 |
80 |
0.4 |
60 |
55 |
95 |
90 |
75 |
80 |
90 |
0.5 |
65 |
60 |
105 |
100 |
85 |
90 |
100 |
0.6 |
70 |
65 |
110 |
105 |
90 |
90 |
110 |
0.7 |
75 |
70 |
115 |
110 |
100 |
100 |
115 |
0.8 |
80 (75 Celotex) |
70 |
120 |
115 |
100 |
100 |
120 |
0.9 |
80 |
75 |
125 |
120 |
100 |
100 |
120 |
1.0 |
80 |
75 |
125 |
125 |
100 |
100 |
125 |
|
| |